  • CGZ2000系列开关状态显示器.jpg

CGZ2000 Series Switch Status Display

The switch cabinet intelligent control device is a new type of multi-functional intelligent device developed for the power switch cabinet.

Classification:

Key words:

CGZ2000 Series Switch Status Display

Related Annexes:


immediate consultation

Product Description

CGZ 2000 switch cabinet intelligent control device is a new type of multi-functional intelligent device developed for power switch cabinet.

  

Product Features

The temperature measurement sensor adopts self-charging mode, no built-in battery, and maintenance-free, which reduces maintenance costs and operational risks for users.

Using ZIGBEE short-range wireless communication transmission technology, the signal error correction ability is strong, non-directional, safe and reliable.

The temperature measurement sensor adopts an irregular hollowed-out structure to ensure that the sensor is in close contact with the wall of the static contact to be measured, and does not hinder the normal circulation of air in the contact box, so that the temperature will not rise, thus ensuring the normal and safe operation of the equipment.

 

CHEEGON ELECTRIC

CGZ2000 series switch state intelligent control device

  

Main functions

The device can realize the functions of primary circuit equipment switch status indication, intelligent control of temperature and humidity in the cabinet, circuit breaker control, on-line measurement and alarm of electrical contact temperature (optional), human body induction and high-voltage live display according to user requirements.

The device is equipped in the switch cabinet with an integrated layout, which simplifies the panel structure design of the switch cabinet in the past, beautifies the panel layout, and replaces the existing primary circuit analog signs, electromagnetic switch status indicators, grounding indicators, energy storage switches, circuit breaker on/off switches and other control and indicator devices, as well as on-line temperature measuring devices for electrical contacts.

The device is easy to install and has a long service life, can fully meet the needs of the power industry, and can ensure the safe and reliable operation of electrical equipment.

  

Technical parameters

1. Power supply: AC85V ~ 265V 50Hz or DC110V/DC220V

2. Environmental conditions

Working temperature:-25 ℃ ~ +55 ℃; storage temperature:-40 ℃ ~ +85 ℃; temperature sensor short-time withstand temperature: 200 ℃. Working relative humidity: 5% RH ~ 95% RH

3. Maximum power consumption: 15W

4. Insulation performance

Dielectric strength: the device can withstand 2KV/50Hz/1Min; power frequency withstand voltage test; insulation resistance: ≥ 100MQ

5. Anti-electromagnetic interference function: meet the requirements of GB/T14598.26.

6. Dynamic simulation primary wiring diagram

Production of simulation diagram (mask): the mask is designed according to the actual primary wiring scheme and voltage level (35k V is lemon yellow, 10kV is magenta, 6kV is dark blue).

Dynamic simulation objects: circuit breaker, handcart position, grounding switch, energy storage, etc., through circuit sampling, dynamically change the wiring diagram on the mask according to the actual information, so as to achieve the purpose of dynamic simulation.

The display of the simulation chart is as follows:

1) Opening (or circuit) display

2) Closing (or loop) display

3) Pre-closing flashing indication

4) Grounding display

5) Energy storage display

6) Display of working position

7) Test position display

8) Dynamic display of handcart in and out process

9) Prompt for anti-error flashing of circuit breaker and grounding switch

7. Voice anti-error prompt function

1) When the trolley is pushed from the test position to the working position by mistake in the closing state of the circuit breaker, the voice prompt "Please open the circuit breaker" will be prompted ".

2) In the closing state of the grounding switch, when the trolley is pushed from the test position to the working position by mistake, the voice prompt "Please separate the grounding switch".

3) When the closing state of the circuit breaker and the closing state of the grounding switch are pushed from the test position to the working position by mistake, the voice prompt "please separate the circuit breaker, please separate the grounding switch".

4) When the main circuit of the cabinet has been powered and someone stays in front of the cabinet, the voice will prompt "the main circuit of the cabinet has been electrified".

8. Operation function

1) Opening and closing operation

2) Energy storage operation

3) Remote/local operation

4) Lighting operation in cabinet

9. Live display function

1) LED starting voltage (kV): bus voltage x0.15

2) Locking start-up control voltage (kV): bus voltage x040

3) When the three phases are not charged at the same time, the lock release light is on and the electromagnetic lock is activated.

Note: Forced locking control power supply: AC or DC 220V, which can ensure the reliable operation of the locking part; the control power supply disappears during operation, the locking contact will not malfunction, and the locked equipment is still reliably locked.

Note: the customer can according to the following technical parameters, the selection of high voltage charged sensor.

Table 4-1 Technical Parameters of High Voltage Charged Sensor

 

CHEEGON ELECTRIC

 

10. Temperature and humidity control function in cabinet

Temperature measurement range: 0C ~ 99 ℃

Humidity measurement range: 0% RH ~ 99% RH

Measurement accuracy: temperature: ± 2 ℃

Humidity: ± 5% RH

It can be equipped with 1~4-way temperature and humidity sensor and output contact, which can display the temperature and humidity measured value in the cabinet.

Users can set the upper and lower limits of heating/dehumidification output according to their needs

11. Electrical contact temperature measurement function

Temperature measurement range:-40C ~ 125 ℃ Temperature measurement accuracy: ± 3C

Wireless transceiver frequency: 24~2.524 GHz Data retention time: ≥ 5 years

Contact temperature measurement points: support 18 points, two space

Distance between temperature sensor (temperature measurement at electrical contact) and receiver: & lt;6m (in the same wireless enclosed space) Distance between receiver and main control device:(RS-485 bus) & lt;800m

12. Communication function: communication function with RS-485 bus, communication protocol conforms to IEC MODBUS

13. Dimensions 238 (long) x178 (high) x105 (deep)(mm)

14 hole size 220 (long) x163 (high)(mm)

15. Installation method: panel installation

Appendix: CGZ2000 Backplane Terminal Wiring Diagram

 

CHEEGON ELECTRIC


CGR-HA-1 Series High Voltage Soft Starter (Standard)

It can reduce the current impact in the starting process of 3kV-10kV motor, protect the mechanical structure, and protect the start and operation of high-voltage motor.


GKGR Series High Voltage Soft Starter (Mine General Type)

A high-pressure soft starting device developed for the mining industry has excellent starting effect for the starting of mine fans, water pumps, crushers and other loads.


CGR-HA-1E Series High Voltage Soft Starter (Integrated)

It can reduce the current impact in the starting process of 3kV-10kV motor, protect the mechanical structure, and protect the start and operation of high-voltage motor.

immediate consultation

If you are interested in our products, please leave your email, we will contact you as soon as possible, thank you!

Submit Message